Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Transplant Cell Ther ; 27(8): 697.e1-697.e5, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33991721

RESUMEN

As a result of the COVID-19 pandemic, most centers performing allogeneic hematopoietic cell transplantation (allo-HCT) have switched to the use of cryopreserved grafts. Previous investigators have suggested that cryopreserved allografts may heighten risk of nonengraftment. To date, no study has investigated the effect of cryopreservation of CD34-selected hematopoietic progenitor cells (CD34+ HPCs) used as the sole graft source. In this study, we sought to evaluate outcomes after unrelated donor or matched sibling allo-HCT with cryopreserved CD34+ HPCs. This was a single-center analysis of adult patients with hematologic malignancies who underwent allo-HCT with cryopreserved CD34-selected allo-HCT grafts between January 2010 and June 2017. All patients received ablative conditioning and antirejection prophylaxis with rabbit antithymocyte globulin. G-CSF-mobilized leukapheresis products underwent CD34 selection using the CliniMACS Reagent System. Cells were then cryopreserved in DMSO (final concentration 7.5%) to -90 °C using a controlled-rate freezing system before being transferred to vapor-phase liquid nitrogen storage. In internal validation, this method has shown 92% mean CD34+ cell viability and 99.7% mean CD34+ cell recovery. Engraftment was defined as the first of 3 consecutive days of an absolute neutrophil count of ≥0.5. Platelet recovery was recorded as the first of 7 consecutive days with a platelet count ≥20 K/µL without transfusion. Kaplan-Meier methodology was used to estimate overall survival (OS) and relapse-free survival (RFS), and cumulative incidence functions were used to estimate rates of relapse, nonrelapse mortality (NRM), and acute graft-versus-host disease (GVHD). A total of 64 patients received a cryopreserved CD34-selected graft. The median CD34+ cell count before cryopreservation was 6.6 × 106/kg (range, 1.4 to 16.1 × 106/kg), and the median CD3+ cell count was 2.0 × 103/kg (range, 0 to 21.1 × 106/kg). All patients were engrafted, at a median of 11 days post-HCT (range, 8 to 14 days). One patient had poor graft function in the setting of cytomegalovirus viremia, necessitating a CD34-selected boost on day +57. The median time to platelet recovery was 16 days (range, 13 to 99 days). The estimated 2-year OS was 70% (95% confidence interval [CI], 58% to 83%) with cryopreserved grafts versus 62% (95% CI, 57% to 67%) with fresh grafts (hazard ratio [HR], 0.86; 95% CI, 0.54 to 1.35; P = .5). The estimated 2-year RFS in the 2 groups was 59% (95% CI, 48% to 74%) versus 56% (95% CI, 51% to 61%; HR, 1.01; 95% CI, 0.68 to 1.51; P > .9). The cumulative incidence of relapse at 2 years was 29% (95% CI, 17% to 41%) versus 23% (95% CI, 19% to 27%; P = .16), and the cumulative incidence of NRM at 2 years was 17% (95% CI, 9% to 28%) versus 23% (95% CI, 19% to 28%; P = .24). The cumulative incidence of grade II-IV acute GVHD by day +100 was 16% with cryopreserved grafts (95% CI, 8% to 26%) and 16% (95% CI, 13% to 20%; P = .97) with fresh grafts. Moderate to severe chronic GVHD by day +365 occurred in only 1 recipient of a cryopreserved graft (2%). Our data show that in patients with hematologic malignancies who received cryopreserved allogeneic CD34+ HPCs, engraftment, GVHD, and survival outcomes were consistent with those seen in recipients of fresh allogeneic CD34+ HPC grafts at our center. Our laboratory validation and clinical experience demonstrate the safety of our cryopreservation procedure for CD34-selected allografts.


Asunto(s)
COVID-19 , Trasplante de Células Madre Hematopoyéticas , Adulto , Criopreservación , Humanos , Recurrencia Local de Neoplasia , Pandemias , SARS-CoV-2
3.
Adv Cell Gene Ther ; 1(2)2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30873513

RESUMEN

INTRODUCTION: CD34+ cell enumeration is a critical parameter used to determine the timing of apheresis collections of hematopoietic progenitor cell products (HPC(A)). Automated hematology analyzers equipped with flow cytometry capabilities may be a solution to the problem of limited access to standard flow cytometry testing. METHODS: We compared CD34+ cell enumeration using a reference flow cytometry procedure employing modified International Society of Hematotherapy and Graft Engineering (ISHAGE) analysis with a hematology analyzer /flow cytometer hybrid (CELL DYN (CD)Sapphire) using a sequential gating analysis designed to emulate the ISHAGE gating strategy. RESULTS: CD34+ cell values obtained from the ISHAGE and CD Sapphire analysis were plotted and compared in a linear regression analysis which showed a high degree of correlation (R2=0.96). No statistically significant (p=0.53) differences in CD34+ cell enumeration values were observed between the flow cytometer and automated hematology analyzer using manual analysis schema. CONCLUSIONS: We have demonstrated that an automated hematology analyzer equipped with a flow module can provide CD34+ cell enumeration results in the peripheral blood for clinical decision algorithms without the need for a dedicated flow cytometry laboratory.

4.
Transfusion ; 56(5): 1008-12, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26919388

RESUMEN

Graft-versus-host disease remains the most important source of morbidity and mortality associated with allogeneic stem cell transplantation. The implementation of hematopoietic progenitor cell (HPC) selection is employed by some stem cell processing facilities to mitigate this complication. Current cell selection methods include reducing the number of unwanted T cells (negative selection) and/or enriching CD34+ hematopoietic stem/progenitors (positive selection) using immunomagnetic beads subjected to magnetic fields within columns to separate out targeted cells. Unwanted side effects of cell selection as a result of T-cell reduction are primary graft failure, increased infection rates, delayed immune reconstitution, possible disease relapse, and posttransplant lymphoproliferative disease. The Miltenyi CliniMACS cell isolation system is the only device currently approved for clinical use by the Food and Drug Administration. It uses magnetic microbeads conjugated with a high-affinity anti-CD34 monoclonal antibody capable of binding to HPCs in marrow, peripheral blood, or umbilical cord blood products. The system results in significantly improved CD34+ cell recoveries (50%-100%) and consistent 3-log CD3+ T-cell reductions compared to previous generations of CD34+ cell selection procedures. In this article, the CliniMACS procedure is described in greater detail and the authors provide useful insight into modifications of the system. Successful implementation of cell selection procedures can have a significant positive clinical effect by greatly increasing the pool of donors for recipients requiring transplants. However, before a program implements cell selection techniques, it is important to consider the time and financial resources required to properly and safely perform these procedures.


Asunto(s)
Antígenos CD34/inmunología , Células Madre Hematopoyéticas/citología , Antígenos CD34/aislamiento & purificación , Enfermedad Injerto contra Huésped/etiología , Enfermedad Injerto contra Huésped/prevención & control , Trasplante de Células Madre Hematopoyéticas/efectos adversos , Trasplante de Células Madre Hematopoyéticas/mortalidad , Humanos , Separación Inmunomagnética
5.
Transfusion ; 56(2): 528-32, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26395285

RESUMEN

BACKGROUND: Allogeneic hematopoietic stem cell donor selection is based primarily on human leukocyte antigen degree of match and it often occurs without regard to the red blood cell (RBC) compatibility between donor and recipient. When major ABO-mismatched grafts are infused, it is imperative that an accurate determination of the incompatible RBC content is made to ensure that the product is safe for infusion. RBC content determination requires the hematocrit (Hct) parameter which can be obtained via manual (directly measured) or automated (calculated) methods. STUDY DESIGN AND METHODS: Ninety-seven apheresis hematopoietic progenitor grafts were assessed for Hct by manual testing and by four commercially available automated hematology analyzer instruments. A clinical model was developed to assess the frequency of unnecessary RBC reductions or alteration in standard infusion practice. RESULTS: Significant (p < 0.001) differences were observed where the manual Hct value was markedly lower than automated Hct values. At stringent incompatible RBC threshold of 10 mL, the number of preventable RBC reduction procedures ranged from 18% to 69%. CONCLUSION: Accurate determination of RBC content of hematopoietic progenitor grafts is essential for patient safety. Despite the rapidity and convenience offered by automated Hct methods, they significantly overestimate the incompatible RBC content of grafts, which may trigger unnecessary RBC reduction procedures or split infusions. In products where automated Hct methods indicate excessive amounts of incompatible RBCs are present, we advise the performance of confirmatory testing with a manual Hct method to ensure that the automated Hct value is not a false positive.


Asunto(s)
Sistema del Grupo Sanguíneo ABO , Eliminación de Componentes Sanguíneos/métodos , Incompatibilidad de Grupos Sanguíneos , Eritrocitos , Células Madre Hematopoyéticas/citología , Modelos Biológicos , Femenino , Hematócrito/métodos , Células Madre Hematopoyéticas/metabolismo , Humanos , Masculino
6.
Blood ; 124(19): 2905-12, 2014 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-25185264

RESUMEN

We investigated the unit characteristics associated with engraftment after double-unit cord blood (CB) transplantation (dCBT) and whether these could be reliably identified during unit selection. Cumulative incidence of neutrophil engraftment in 129 myeloablative dCBT recipients was 95% (95% confidence interval: 90-98%). When precryopreservation characteristics were analyzed, the dominant unit CD34(+) cell dose was the only characteristic independently associated with engraftment (hazard ratio, 1.43; P = .002). When postthaw characteristics were also included, only dominant unit infused viable CD34(+) cell dose independently predicted engraftment (hazard ratio, 1.95; P < .001). We then examined the determinants of infused viable CD34(+) cell dose (precryopreservation count, postthaw recovery, and postthaw viability) in 402 units thawed at our center. This revealed close correlation between precryopreservation and postthaw CD34(+) cell counts (r(2) = 0.73). Median CD34(+) cell recovery was 101%, although it ranged from 12% to 1480%. Notably, units from non-Netcord Foundation for the Accreditation of Cellular Therapy (Netcord-FACT)-accredited banks were more likely to have low recovery (P < .001). Furthermore, although median postthaw CD34(+) cell viability was 92%, 33 (8%) units had <75% viable CD34(+) cells. Units from non-Netcord-FACT-accredited banks and units with cryovolumes other than 24.5 to 26.0 mL were more likely to have poor postthaw viability. Precryopreservation CD34(+) cell dose and banking practices should be incorporated into CB unit selection.


Asunto(s)
Almacenamiento de Sangre/métodos , Trasplante de Células Madre de Sangre del Cordón Umbilical/métodos , Neoplasias Hematológicas/terapia , Trasplante de Células Madre Hematopoyéticas/métodos , Neutrófilos/trasplante , Adolescente , Adulto , Anciano , Antígenos CD34/metabolismo , Biomarcadores/metabolismo , Conservación de la Sangre/métodos , Separación Celular/métodos , Niño , Preescolar , Criopreservación/métodos , Supervivencia de Injerto , Humanos , Lactante , Persona de Mediana Edad , Adulto Joven
7.
Biol Blood Marrow Transplant ; 20(4): 490-4, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24361912

RESUMEN

Washing cord blood (CB) grafts involves product manipulation and may result in cell loss. We investigated double-unit CB transplantation (CBT) using red blood cell (RBC)-depleted units diluted with albumin-dextran in patients with hematologic malignancies. One-hundred thirty-six patients (median age, 43 years; range, 4 to 71; median weight, 69 kilograms (kg); range, 24 to 111) underwent transplantation with a 4/6 to 6/6 HLA-matched graft. Patients ≤ 20 kg were excluded, as they only received washed units. Units were diluted a median of 8 fold to a median volume of 200 mL/unit. The median infused total nucleated cell doses were 2.7 (larger unit) and 2.0 (smaller unit) x 10(7)/kg, respectively, and the median post-thaw recovery was 86%. Units were infused consecutively (median, 45 minutes/unit). While only 17 patients (13%) had no infusion reactions, reactions in the remaining 119 patients were almost exclusively mild-moderate (by CTCAE v4 criteria 12 grade 1, 43 grade 2, 63 grade 3) with only 1 patient (< 1%) having a severe (grade 4) reaction. Moreover, most were easily treated. Grade 2 to 3 hypertension was the most common in 101 (74%) patients. The cumulative incidence of sustained donor-derived neutrophil engraftment was high: 95% in myeloablative and 94% in nonmyeloablative CBT recipients. With appropriate supportive care, double-unit CBT with RBC-depleted grafts infused after albumin-dextran dilution is safe with high rates of engraftment in patients > 20 kg.


Asunto(s)
Trasplante de Células Madre de Sangre del Cordón Umbilical/métodos , Supervivencia de Injerto , Neoplasias Hematológicas/terapia , Acondicionamiento Pretrasplante , Adolescente , Adulto , Anciano , Niño , Preescolar , Dextranos/administración & dosificación , Femenino , Antígenos HLA/inmunología , Neoplasias Hematológicas/inmunología , Neoplasias Hematológicas/patología , Prueba de Histocompatibilidad , Humanos , Masculino , Persona de Mediana Edad , Agonistas Mieloablativos/uso terapéutico , Vehículos Farmacéuticos/administración & dosificación , Estudios Retrospectivos , Albúmina Sérica/administración & dosificación , Resultado del Tratamiento
8.
J Nurs Care Qual ; 18(1): 56-60, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12518839

RESUMEN

UNLABELLED: A four-pronged approach to improving the blood product delivery system resulted in a significant decrease in the number of blood products ordered STAT, increased ability of the blood bank to fulfill STAT requests in a timely manner, and a significant decrease in the number of blood products outdated and discarded. KEYWORDS: blood products, performance improvement


Asunto(s)
Bancos de Sangre/normas , Transfusión Sanguínea/estadística & datos numéricos , Sistemas de Distribución en Hospital/normas , Gestión de la Calidad Total/métodos , Transfusión Sanguínea/enfermería , Control de Costos , Eficiencia Organizacional , Humanos , Equipos de Administración Institucional , Ciudad de Nueva York , Administración del Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...